Trane Comfort SpecialistCall (210) 495-7771
Trane · S9B1Trane S9B1 92 Single-Stage Builder-Grade Gas FurnaceTrane S9B1 92 Single-Stage Builder-Grade Gas Furnace — angle view
Trane · Gas furnaces

Trane S9B1 92 Single-Stage Builder-Grade Gas Furnace

Single-stageAlso known as S9B111 models

At a glance

How it runs
Single-stage
Fuel efficiency
Up to 92% AFUE
Heating stages
One
Fuel
gas
ENERGY STAR®
Available on qualifying matches
Sizes
3–5 tons

What’s built in

  • Self-diagnostic integrated furnace control board (IFC)
  • Silicon nitride hot surface igniter
  • Multi-port, in-shot burners
  • Pre-painted, heavy steel cabinet
  • Insulated heat exchanger compartment
  • Tubular, stainless steel heat exchanger
  • This product was formerly known as the S9B1 Gas Furnace

Every model

ModelTonsEnergy guide
S9B1B040D3PSA3PDF
S9B1B040U3PSA3PDF
S9B1B060D3PSA3PDF
S9B1B060U4PSA4PDF
S9B1B080D4PSA4PDF
S9B1B080U4PSA4PDF
S9B1C080U5PSA5PDF
S9B1C100D5PSA5PDF
S9B1C100U5PSA5PDF
S9B1D120D5PSA5PDF
S9B1D120U5PSA5PDF

11 models · 2 columns · swipe the table sideways on a phone

Full spec sheets

11 of 11 models have a full spec sheet below.

S9B1B040D3PSA3 ton · 31 data points
Type
Downflow
Input BTUH
40,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Downflow
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
0.5
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
2.1
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
2 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
2
S9B1B040U3PSA3 ton · 31 data points
Type
Upflow / Horizontal
Input BTUH
40,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Upflow / Horizontal
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
0.5
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
2.1
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
2 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
2
S9B1B060D3PSA3 ton · 31 data points
Type
Downflow
Input BTUH
60,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Downflow
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
0.5
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
2.1
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
3 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
3
S9B1B060U4PSA4 ton · 31 data points
Type
Upflow / Horizontal
Input BTUH
60,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Upflow / Horizontal
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
0.8
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
8.4
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
2.1
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
3 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
3
S9B1B080D4PSA4 ton · 32 data points
Type
Downflow
Input BTUH
80,000
Capacity BTUH (ICS)
76,900
Temp. Rise (Min. - Max.) °F
45-75
AFUE (%)
92.1
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
1
Energy Star Rated Region
US - South
Energy Star Rated Region On
N/A
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
0.8
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
9.3
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
2.1
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 17-1/2 x 28-3/4
Crated (in.)
35-1/2 x 19-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
135/127
S9B1B080U4PSA4 ton · 31 data points
Type
Upflow / Horizontal
Input BTUH
80,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Upflow / Horizontal
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
0.8
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
8.4
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
2.1
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
4 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
4
S9B1C080U5PSA5 ton · 31 data points
Type
Upflow / Horizontal
Input BTUH
80,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Upflow / Horizontal
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
1.0
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
0.7
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
4 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
4
S9B1C100D5PSA5 ton · 32 data points
Type
Downflow
Input BTUH
100,000
Capacity BTUH (ICS)
96,800
Temp. Rise (Min. - Max.) °F
40-70
AFUE (%)
92.1
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
1
Energy Star Rated Region
US - South
Energy Star Rated Region On
N/A
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
1.0
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
0.7
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Crated (in.)
35-1/2 x 23 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
155/145
S9B1C100U5PSA5 ton · 31 data points
Type
Upflow / Horizontal
Input BTUH
100,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Upflow / Horizontal
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
1.0
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
0.7
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
5 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
5
S9B1D120D5PSA5 ton · 32 data points
Type
Downflow
Input BTUH
120,000
Capacity BTUH (ICS)
115,500
Temp. Rise (Min. - Max.) °F
45-75
AFUE (%)
92.1
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
1
Energy Star Rated Region
US - South
Energy Star Rated Region On
N/A
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
1.0
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
0.7
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 24 X 25 - 1 in.
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 24-1/2 x 28-3/4
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
167/156
S9B1D120U5PSA5 ton · 32 data points
S9X1 Dedicated Downflow models
S9B1 Dedicated Downflow models
Type
Upflow / Horizontal
Input BTUH
120,000
AFUE (%)
92.1
CEE Tier
1
Region Before July 31,
US - South
Region On or After July
N/A
Energy Star Orientation
Upflow / Horizontal
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
1.0
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Type · FLA
0.7
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 24 X 25 - 1 in.
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
6 - 45
Gas Valve
Redundant - One Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
6

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More Trane gas furnaces

Call now