Trane Comfort SpecialistCall (210) 495-7771
Trane · S9V2-VSTrane S9V2-VS 97 Two-Stage Variable Speed Gas FurnaceTrane S9V2-VS 97 Two-Stage Variable Speed Gas Furnace — angle view
Trane · Gas furnaces

Trane S9V2-VS 97 Two-Stage Variable Speed Gas Furnace

Variable speedAlso known as S9V2-VS11 models

At a glance

How it runs
Variable speed
Fuel efficiency
Up to 97% AFUE
Heating stages
Two
Fuel
gas
ENERGY STAR®
Available on qualifying matches
Sizes
3–5 tons

What’s built in

  • Re-designed cabinet platform to fit in tighter spaces
  • Variable-speed blower motor
  • Variable Speed Draft Inducer
  • Heavy gauge, two-tone powder-painted cabinet
  • Increased dehumidification with Comfort-R™
  • Stainless steel primary and secondary heat exchanger
  • Insulated cabinet for quiet operation
  • This product was formerly known as the S9V2-VS Gas Furnace

Every model

ModelTonsHeight (in)Width (in)Depth (in)Energy guide
S9V2B040D3VSB*33417.528.8—
S9V2B040U3VSB*33417.528.8PDF
S9V2B060D3VSB*33417.528.8PDF
S9V2B060U4VSB*43417.528.8—
S9V2B080D4VSB*43417.528.8PDF
S9V2B080U4VSB*43417.528.8PDF
S9V2C080U5VSB*53421.028.8—
S9V2C100D5VSB*53421.028.8—
S9V2C100U5VSB*53421.028.8—
S9V2D120D5VSB*53424.528.8—
S9V2D120U5VSB*53424.528.8—

11 models · 5 columns · swipe the table sideways on a phone

Full spec sheets

11 of 11 models have a full spec sheet below.

S9V2B040D3VSB*3 ton · 45 data points
Type
Downflow
1st Stage Input BTUH
26,000
1st Stage Capacity BTUH (ICS)
25,050
2nd Stage Input BTUH
40,000
2nd Stage Capacity BTUH (ICS)
38,800
1st Stage Temp. Rise (Min. - Max.) °F
25- 55
2nd Stage Temp. Rise (Min. - Max.) °
30 - 60
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or After
US - All/Canada
Energy Star Orientation
Downflow
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 8
No. Used
1
Speeds (No.)
Variable
CFM vs. in. w.g
Performance
Motor HP
1/2
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
Motor RPM
1/50 - 5000
Integrated Furnace Control · FLA
0.77
Inducer Orifice
0.61
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 x 25 - 1 in.
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
2 - 45
Propane Gas (Qty. - Drill Size)
2 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device / Type
120 V SiNi Igniter
Burners - Type - Qty
Inshot - 2
Power Conn. - V/Ph/Hz
120 / 1 / 60
Ampacity (Amps)
8.9
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
122/114
S9V2B040U3VSB*3 ton · 49 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
26,000
1st Stage Capacity BTUH (ICS)
25,700
2nd Stage Input BTUH
40,000
2nd Stage Capacity BTUH (ICS)
39,350
1st Stage Temp. Rise (Min. - Max.)
25 - 55
2nd Stage Temp. Rise (Min
30 - 60
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or
US - All/Canada
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 8
No. Used
1
Speeds (No.)
Variable
Integrated Furnace Control
CFM vs. in. w.g.
Motor HP
1/2
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
HP and Max Motor RPM
1/50 - 5000
Volts/Ph/Hz
180
Volts/Ph/Hz · FLA
0.77
Inducer Orifice
0.61
Filter - Furnished?
No
Type Recommended
High Velocity
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Heat Exchanger / Type
409 Stainless
Fired
Steel
Unfired
Steel
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
2 - 45
Propane Gas (Qty. - Drill Size)
2 - 56
Orifices - Main
Redundant - Two
Gas Valve
Stage
Burners - TYPE - QTY
Inshot - 2
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
8.9
Max. Overcurrent Protection
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Dimensions (HxWxD)
35-1/2 x 19-1/2 x
Crated (in.)
30-7/8
Shipping (lbs.)/Net (lbs.)
122/114
S9V2B060D3VSB*3 ton · 45 data points
Type
Downflow
1st Stage Input BTUH
39,000
1st Stage Capacity BTUH (ICS)
38,500
2nd Stage Input BTUH
60,000
2nd Stage Capacity BTUH (ICS)
58,200
1st Stage Temp. Rise (Min. - Max.) °F
25- 55
2nd Stage Temp. Rise (Min. - Max.) °
35 - 65
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or After
US - All/Canada
Energy Star Orientation
Downflow
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 8
No. Used
1
Speeds (No.)
Variable
CFM vs. in. w.g
Performance
Motor HP
1/2
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
Motor RPM
1/50 - 5000
Integrated Furnace Control · FLA
0.77
Inducer Orifice
0.79
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 x 25 - 1 in.
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
3- 45
Propane Gas (Qty. - Drill Size)
3- 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device / Type
120 V SiNi Igniter
Burners - Type - Qty
Inshot - 3
Power Conn. - V/Ph/Hz
120 / 1 / 60
Ampacity (Amps)
8.9
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
127/119
S9V2B060U4VSB*4 ton · 49 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
39,000
1st Stage Capacity BTUH (ICS)
38,450
2nd Stage Input BTUH
60,000
2nd Stage Capacity BTUH (ICS)
57,700
1st Stage Temp. Rise (Min. - Max.)
25 - 55
2nd Stage Temp. Rise (Min
35 - 65
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or
US - All/Canada
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 8
No. Used
1
Speeds (No.)
Variable
Integrated Furnace Control
Performance
Motor HP
3/4
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
9.6
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
HP and Max Motor RPM
1/50 - 5000
Volts/Ph/Hz
180
Volts/Ph/Hz · FLA
0.77
Inducer Orifice
0.79
Filter - Furnished?
No
Type Recommended
High Velocity
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Heat Exchanger / Type
409 Stainless
Fired
Steel
Unfired
Steel
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
3 - 45
Propane Gas (Qty. - Drill Size)
3 - 56
Orifices - Main
Redundant - Two
Gas Valve
Stage
Burners - TYPE - QTY
Inshot - 3
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
12.9
Max. Overcurrent Protection
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Dimensions (HxWxD)
35-1/2 x 19-1/2 x
Crated (in.)
30-7/8
Shipping (lbs.)/Net (lbs.)
130/122
S9V2B080D4VSB*4 ton · 45 data points
Type
Downflow
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
51,150
2nd Stage Input BTUH
80,000
2nd Stage Capacity BTUH (ICS)
76,900
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
2nd Stage Temp. Rise (Min. - Max.) °
35 - 65
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or After
US - All/Canada
Energy Star Orientation
Downflow
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 8
No. Used
1
Speeds (No.)
Variable
CFM vs. in. w.g
Performance
Motor HP
3/4
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
9.6
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
Motor RPM
1/50 - 5000
Integrated Furnace Control · FLA
0.77
Inducer Orifice
0.96
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 x 25 - 1 in.
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
4- 45
Propane Gas (Qty. - Drill Size)
4- 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device / Type
120 V SiNi Igniter
Burners - Type - Qty
Inshot - 4
Power Conn. - V/Ph/Hz
120 / 1 / 60
Ampacity (Amps)
12.9
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
135/127
S9V2B080U4VSB*4 ton · 49 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
51,050
2nd Stage Input BTUH
80,000
2nd Stage Capacity BTUH (ICS)
76,700
1st Stage Temp. Rise (Min. - Max.)
30 - 60
2nd Stage Temp. Rise (Min
35 - 65
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or
US - All/Canada
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 8
No. Used
1
Speeds (No.)
Variable
Integrated Furnace Control
Performance
Motor HP
3/4
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
9.6
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
HP and Max Motor RPM
1/50 - 5000
Volts/Ph/Hz
180
Volts/Ph/Hz · FLA
0.77
Inducer Orifice
0.96
Filter - Furnished?
No
Type Recommended
High Velocity
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Heat Exchanger / Type
409 Stainless
Fired
Steel
Unfired
Steel
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
4 - 45
Propane Gas (Qty. - Drill Size)
4 - 56
Orifices - Main
Redundant - Two
Gas Valve
Stage
Burners - TYPE - QTY
Inshot - 4
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
12.9
Max. Overcurrent Protection
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Dimensions (HxWxD)
35-1/2 x 19-1/2 x
Crated (in.)
30-7/8
Shipping (lbs.)/Net (lbs.)
135/127
S9V2C080U5VSB*5 ton · 49 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
51,300
2nd Stage Input BTUH
80,000
2nd Stage Capacity BTUH (ICS)
77,450
1st Stage Temp. Rise (Min. - Max.)
30 - 60
2nd Stage Temp. Rise (Min
30 - 60
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or
US - All/Canada
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 8
No. Used
1
Speeds (No.)
Variable
Integrated Furnace Control
Performance
Motor HP
1
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
10
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
HP and Max Motor RPM
1/50 - 5000
Volts/Ph/Hz
180
Volts/Ph/Hz · FLA
0.77
Inducer Orifice
0.88
Filter - Furnished?
No
Type Recommended
High Velocity
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Heat Exchanger / Type
409 Stainless
Fired
Steel
Unfired
Steel
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
4 - 45
Propane Gas (Qty. - Drill Size)
4 - 56
Orifices - Main
Redundant - Two
Gas Valve
Stage
Burners - TYPE - QTY
Inshot - 4
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
13.4
Max. Overcurrent Protection
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Dimensions (HxWxD)
35-1/2 x 23 x
Crated (in.)
30-7/8
Shipping (lbs.)/Net (lbs.)
149/139
S9V2C100D5VSB*5 ton · 45 data points
Type
Downflow
1st Stage Input BTUH
65,000
1st Stage Capacity BTUH (ICS)
64,000
2nd Stage Input BTUH
100,000
2nd Stage Capacity BTUH (ICS)
97,350
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
2nd Stage Temp. Rise (Min. - Max.) °
35 - 65
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or After
US - All/Canada
Energy Star Orientation
Downflow
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 10
No. Used
1
Speeds (No.)
Variable
CFM vs. in. w.g
Performance
Motor HP
1
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
10
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
Motor RPM
1/50 - 5000
Integrated Furnace Control · FLA
0.77
Inducer Orifice
1.05
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 x 25 - 1 in.
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
5 - 45
Propane Gas (Qty. - Drill Size)
5 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device / Type
120 V SiNi Igniter
Burners - Type - Qty
Inshot - 5
Power Conn. - V/Ph/Hz
120 / 1 / 60
Ampacity (Amps)
13.4
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
154/144
S9V2C100U5VSB*5 ton · 49 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
65,000
1st Stage Capacity BTUH (ICS)
64,200
2nd Stage Input BTUH
100,000
2nd Stage Capacity BTUH (ICS)
97,150
1st Stage Temp. Rise (Min. - Max.)
25 - 55
2nd Stage Temp. Rise (Min
35 - 65
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or
US - All/Canada
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 10
No. Used
1
Speeds (No.)
Variable
Integrated Furnace Control
Performance
Motor HP
1
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
10
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
HP and Max Motor RPM
1/50 - 5000
Volts/Ph/Hz
180
Volts/Ph/Hz · FLA
0.77
Inducer Orifice
1.05
Filter - Furnished?
No
Type Recommended
High Velocity
Vent Outlet Dia - Min. (in.)
2 Round
Inlet Air Dia - Min. (in.)
2 Round
Heat Exchanger / Type
409 Stainless
Fired
Steel
Unfired
Steel
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
5 - 45
Propane Gas (Qty. - Drill Size)
5 - 56
Orifices - Main
Redundant - Two
Gas Valve
Stage
Burners - TYPE - QTY
Inshot - 5
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
13.4
Max. Overcurrent Protection
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Dimensions (HxWxD)
35-1/2 x 23 x
Crated (in.)
30-7/8
Shipping (lbs.)/Net (lbs.)
154/144
S9V2D120D5VSB*5 ton · 45 data points
Type
Downflow
1st Stage Input BTUH
78,000
1st Stage Capacity BTUH (ICS)
75,660
2nd Stage Input BTUH
120,000
2nd Stage Capacity BTUH (ICS)
116,400
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
2nd Stage Temp. Rise (Min. - Max.) °
35 - 65
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or After
US - All/Canada
Energy Star Orientation
Downflow
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 10
No. Used
1
Speeds (No.)
Variable
CFM vs. in. w.g
Performance
Motor HP
1
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
10
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
Motor RPM
1/50 - 5000
Integrated Furnace Control · FLA
0.77
Inducer Orifice
1.19
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 24 x 25 - 1 in.
Vent Outlet Dia - Min. (in.)
3 Round
Inlet Air Dia - Min. (in.)
3 Round
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
6- 45
Propane Gas (Qty. - Drill Size)
6- 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device / Type
120 V SiNi Igniter
Burners - Type - Qty
Inshot - 6
Power Conn. - V/Ph/Hz
120 / 1 / 60
Ampacity (Amps)
13.4
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
167/156
S9V2D120U5VSB*5 ton · 49 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
78,000
1st Stage Capacity BTUH (ICS)
77,050
2nd Stage Input BTUH
120,000
2nd Stage Capacity BTUH (ICS)
116,250
1st Stage Temp. Rise (Min. - Max.)
35 - 65
2nd Stage Temp. Rise (Min
40 - 70
AFUE (%)
97.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
CEE Tier
Tier 3
Energy Star Rated Region Before
US - All/Canada
Energy Star Rated Region On or
US - All/Canada
Input–Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 x 10
No. Used
1
Speeds (No.)
Variable
Integrated Furnace Control
Performance
Motor HP
1
R.P.M
Variable
Volts / Ph / Hz
120 / 1 / 60
FLA
10
Combustion Fan - Type
Variable Speed
Drive - No. Speeds
Direct - Variable
HP and Max Motor RPM
1/50 - 5000
Volts/Ph/Hz
- 180
Volts/Ph/Hz · FLA
0.77
Inducer Orifice
1.19
Filter - Furnished?
No
Type Recommended
High Velocity
Vent Outlet Dia - Min. (in.)
3 Round
Inlet Air Dia - Min. (in.)
3 Round
Heat Exchanger / Type
409 Stainless
Fired
Steel
Unfired
Stainless Steel
Gauge (Fired)
20
Nat. Gas (Qty. - Drill Size)
6 - 45
Propane Gas (Qty. - Drill Size)
6 - 56
Orifices - Main
Redundant -
Gas Valve
Two Stage
Burners - TYPE - QTY
Inshot - 6
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
13.4
Max. Overcurrent Protection
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Dimensions (HxWxD)
35-1/2 x 26-1/2
Crated (in.)
x 30-7/8
Shipping (lbs.)/Net (lbs.)
167/156

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More Trane gas furnaces

Call now