Trane Comfort SpecialistCall (210) 495-7771
Trane · S9X2Trane S9X2 96 Two-Stage Gas FurnaceTrane S9X2 96 Two-Stage Gas Furnace — angle view
Trane · Gas furnaces

Trane S9X2 96 Two-Stage Gas Furnace

Two-stageAlso known as S9X211 models

At a glance

How it runs
Two-stage
Fuel efficiency
Up to 96% AFUE
Heating stages
Two
Fuel
gas
ENERGY STAR®
Available on qualifying matches
Sizes
3–5 tons

What’s built in

  • Re-designed cabinet platform to fit in tighter spaces
  • CTM blower motor
  • Heavy gauge, two-tone powder-painted cabinet
  • Stainless steel primary and secondary heat exchanger
  • Insulated cabinet for quiet operation
  • 2 stage gas heat — more comfort, quieter operation, less temperature swing
  • ECM Constant Torque, high-efficiency motor — electrically efficient
  • Stainless steel primary and secondary heat exchangers — reliable / durable
  • Three-way poise (U, HL, HR) plus dedicated DF — getting the right model is easier
  • 24v IFC — compatible with most thermostats
  • Matches with single stage or 2 stage AC or HP — more system design flexibility
  • 34” height — easy to fit in tight places or with larger coils
  • Easy to install and service — dealer friendly design
  • Certified 1% airtight — meets the most stringent building codes
  • This product was formerly known as the S9X2 Gas Furnace

Every model

ModelTonsEnergy guide
S9X2B040D3PSB3PDF
S9X2B040U3PSB3PDF
S9X2B060D3PSB3PDF
S9X2B060U4PSB4PDF
S9X2B080D4PSB4PDF
S9X2B080U4PSB4PDF
S9X2C080U5PSB5PDF
S9X2C100D5PSB5PDF
S9X2C100U5PSB5PDF
S9X2D120D5PSB5PDF
S9X2D120U5PSB5PDF

11 models · 2 columns · swipe the table sideways on a phone

Full spec sheets

11 of 11 models have a full spec sheet below.

S9X2B040D3PSB3 ton · 47 data points
Type
Downflow
1st Stage Input BTUH
26,000
1st Stage Capacity BTUH (ICS)
25,220
2nd Stage Input BTUH
40,000
1st Stage Temp. Rise (Min. - Max.) °
25 - 55
2nd Stage Temp. Rise (Min. - Max.)
30 - 60
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
1/2
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
2 - 14 x 20 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
2 - 45
L.P. Gas Qty. - Drill Size
2 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
2
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
8.8
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 17-1/2 x 28-3/4
Crated (in.)
35-1/2 x 19-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
122/114
S9X2B040U3PSB3 ton · 47 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
26,000
1st Stage Capacity BTUH (ICS)
25,220
2nd Stage Input BTUH
40,000
1st Stage Temp. Rise (Min. - Max.) °
25 - 55
2nd Stage Temp. Rise (Min. - Max.)
30 - 60
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Upflow / Horizontal
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
1/2
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
COMBUSTION FAN - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
2 - 45
L.P. Gas Qty. - Drill Size
2 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
2
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
8.8
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 17-1/2 x 28-3/4
Crated (in.)
35-1/2 x 19-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
122/114
S9X2B060D3PSB3 ton · 47 data points
Type
Downflow
1st Stage Input BTUH
39,000
1st Stage Capacity BTUH (ICS)
37,830
2nd Stage Input BTUH
60,000
1st Stage Temp. Rise (Min. - Max.) °
25 - 55
2nd Stage Temp. Rise (Min. - Max.)
35 - 65
AFUE (%)
95.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
1/2
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
2 - 14 x 20 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
3 - 45
L.P. Gas Qty. - Drill Size
3 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
3
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
8.8
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 17-1/2 x 28-3/4
Crated (in.)
35-1/2 x 19-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
127/119
S9X2B060U4PSB4 ton · 47 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
39,000
1st Stage Capacity BTUH (ICS)
37,830
2nd Stage Input BTUH
60,000
1st Stage Temp. Rise (Min. - Max.) °
25 - 55
2nd Stage Temp. Rise (Min. - Max.)
30 - 60
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Upflow / Horizontal
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
3/4
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
8.4
COMBUSTION FAN - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
3 - 45
L.P. Gas Qty. - Drill Size
3 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
3
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
11.3
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 17-1/2 x 28-3/4
Crated (in.)
35-1/2 x 19-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
130/122
S9X2B080D4PSB4 ton · 47 data points
Type
Downflow
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
50,440
2nd Stage Input BTUH
80,000
2nd Stage Capacity BTUH (ICS)
77,600
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
2nd Stage Temp. Rise (Min. - Max.) °F
45-75
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31, 2026
US - All / Canada
Energy Star Rating On or After July 31, 2026
US - South
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
3/4
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
9.3
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
2 - 14 x 20 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
4
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
12.4
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 17-1/2 x 28-3/4
Crated (in.)
35-1/2 x 19-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
135/127
S9X2B080U4PSB4 ton · 47 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
50,440
2nd Stage Input BTUH
80,000
1st Stage Temp. Rise (Min. - Max.) °
30 - 60
2nd Stage Temp. Rise (Min. - Max.)
45 - 75
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Upflow / Horizontal
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
3/4
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
8.4
COMBUSTION FAN - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
4
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
11.3
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 17-1/2 x 28-3/4
Crated (in.)
35-1/2 x 19-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
135/127
S9X2C080U5PSB5 ton · 47 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
50,440
2nd Stage Input BTUH
80,000
1st Stage Temp. Rise (Min. - Max.) °
30 - 60
2nd Stage Temp. Rise (Min. - Max.)
40-70
AFUE (%)
95.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Upflow / Horizontal
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
1
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
COMBUSTION FAN - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
4
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Crated (in.)
35-1/2 x 23 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
149/139
S9X2C100D5PSB5 ton · 47 data points
Type
Downflow
1st Stage Input BTUH
65,000
1st Stage Capacity BTUH (ICS)
63,050
2nd Stage Input BTUH
100,000
2nd Stage Capacity BTUH (ICS)
97,000
1st Stage Temp. Rise (Min. - Max.) °F
25-55
2nd Stage Temp. Rise (Min. - Max.) °F
40-70
AFUE (%)
95.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31, 2026
US - All / Canada
Energy Star Rating On or After July 31, 2026
US - South
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
1
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
2 - 16 x 20 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
5 - 45
L.P. Gas Qty. - Drill Size
5 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
5
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Crated (in.)
35-1/2 x 23 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
155/145
S9X2C100U5PSB5 ton · 47 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
65,000
1st Stage Capacity BTUH (ICS)
63,050
2nd Stage Input BTUH
100,000
1st Stage Temp. Rise (Min. - Max.) °
25 - 55
2nd Stage Temp. Rise (Min. - Max.)
40 - 70
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Upflow / Horizontal
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
1
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
2 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
5 - 45
L.P. Gas Qty. - Drill Size
5 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
5
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28-3/4
Crated (in.)
35-1/2 x 23 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
155/145
S9X2D120D5PSB5 ton · 47 data points
Type
Downflow
1st Stage Input BTUH
78,000
1st Stage Capacity BTUH (ICS)
75,660
2nd Stage Input BTUH
120,000
2nd Stage Capacity BTUH (ICS)
116,400
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
2nd Stage Temp. Rise (Min. - Max.) °F
45-75
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31, 2026
US - All / Canada
Energy Star Rating On or After July 31, 2026
US - South
Energy Star Orientation
Downflow
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
CFM vs. iwc
See Fan Performance Table
Motor HP
1
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
2 - 16 x 20 - 1 in.
Vent Pipe Diameter - Min. (in.)
3 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
6 - 45
L.P. Gas Qty. - Drill Size
6 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
6
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 24-1/2 x 28-3/4
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
167/156
S9X2D120U5PSB5 ton · 47 data points
Type
Upflow / Horizontal
1st Stage Input BTUH
78,000
1st Stage Capacity BTUH (ICS)
75,660
2nd Stage Input BTUH
120,000
1st Stage Temp. Rise (Min. - Max.) °
30 - 60
2nd Stage Temp. Rise (Min. - Max.)
40 - 70
AFUE (%)
96.0
Return Air Temp. (Min.-Max.)
45°F - 80°F
CEE Tier
2
Energy Star Rating Before July 31,
US - All / Canada
Energy Star Rating On or After July
US - South
Energy Star Orientation
Upflow / Horizontal
Input-Communication Protocol
24 Volts
Blower Drive
Direct
Diameter - Width (in.)
11 X 10
No. Used
1
Speeds (No.)
9
Integrated Furnace Control
See Fan Performance
Motor HP
1
R.P.M
1075
Volts / Ph / Hz
120 / 1 / 60
FLA
10.6
Combustion Fan - Type
Centrifugal
Drive - No. Speeds
Direct - 2
Motor HP - RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
CFM vs. iwc · FLA
0.66
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 24 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
3 Round
Fired
409 Stainless Steel
Unfired
29-4C Stainless Steel
Gauge (Fired)
20
Nat. Gas Qty. - Drill Size
6 - 45
L.P. Gas Qty. - Drill Size
6 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device · Type
120 V SiNi Igniter
Burners - Type
Multiport Inshot
Number
6
Power Conn. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Conn. Size (in.)
1/2
Uncrated (in.)
34 x 24-1/2 x 28-3/4
Crated (in.)
35-1/2 x 26-1/2 x 30-7/8
Shipping (Lbs.)/Net (Lbs.)
167/156

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More Trane gas furnaces

Call now