Trane Comfort SpecialistCall (210) 495-7771
Trane · S8X2Trane S8X2 80 Two-Stage Gas FurnaceTrane S8X2 80 Two-Stage Gas Furnace — angle view
Trane · Gas furnaces

Trane S8X2 80 Two-Stage Gas Furnace

Two-stageAlso known as S8X26 models

At a glance

How it runs
Two-stage
Fuel efficiency
Up to 80% AFUE
Heating stages
Two
Fuel
gas

What’s built in

  • Nine tap blower motor
  • Two-stage gas heat
  • Microelectronic controller
  • Heavy steel cabinet
  • Durable silicon nitride hot surface igniter
  • Multi-port, in-shot burners
  • Tubular steel heat exchanger
  • Pre-painted galvanized steel cabinet
  • Insulated cabinet for quiet operation
  • This product was formerly known as the S8X2 Gas Furnace

Every model

ModelHeight (in)Width (in)Depth (in)Energy guide
S8X2A040M3PSC3414.528PDF
S8X2B060M4PSC3417.528PDF
S8X2B080M4PSC3417.528PDF
S8X2C080M5PSC3417.528PDF
S8X2C100M5PSC342128PDF
S8X2D120M5PSC3424.528PDF

6 models · 4 columns · swipe the table sideways on a phone

Full spec sheets

6 of 6 models have a full spec sheet below.

S8X2A040M3PSCSpec sheet · 41 data points
Type
Upflow / Horizontal / Downflow
1st Stage Input BTUH
26,000
1st Stage Capacity BTUH (ICS)
20,900
2nd Stage Input BTUH
40,000
2nd Stage Capacity BTUH (ICS)
32,200
1st Stage Temp. Rise (Min. - Max.) °F
20 - 50
2nd Stage Temp. Rise (Min. - Max.) °F
30 - 60
AFUE (%)
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1/2
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 2
Motor RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.20
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 14 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchnager - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
2 - 45
L.P. Gas Qty. - Drill Size
2 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
2
Power Connection. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
8.5
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 14.5 x 28.75
Crated (in.)
35.5 x 16.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
102 / 94
S8X2B060M4PSCSpec sheet · 41 data points
Type
Upflow / Horizontal / Downflow
1st Stage Input BTUH
39,000
1st Stage Capacity BTUH (ICS)
31,500
2nd Stage Input BTUH
60,000
2nd Stage Capacity BTUH (ICS)
48,700
1st Stage Temp. Rise (Min. - Max.) °F
20 - 50
2nd Stage Temp. Rise (Min. - Max.) °F
30 - 60
AFUE (%)
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
3/4
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
9.2
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 2
Motor RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.40
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchnager - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
3 - 45
L.P. Gas Qty. - Drill Size
3 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
3
Power Connection. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
12.0
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
132 / 124
S8X2B080M4PSCSpec sheet · 41 data points
Type
Upflow / Horizontal / Downflow
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
42,500
2nd Stage Input BTUH
80,000
2nd Stage Capacity BTUH (ICS)
65,000
1st Stage Temp. Rise (Min. - Max.) °F
25 - 55
2nd Stage Temp. Rise (Min. - Max.) °F
30 - 60
AFUE (%)
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
3/4
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
9.2
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 2
Motor RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.75
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchnager - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
4
Power Connection. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
12.0
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
137 / 129
S8X2C080M5PSCSpec sheet · 41 data points
Type
Upflow / Horizontal / Downflow
1st Stage Input BTUH
52,000
1st Stage Capacity BTUH (ICS)
41,800
2nd Stage Input BTUH
80,000
2nd Stage Capacity BTUH (ICS)
64,900
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
2nd Stage Temp. Rise (Min. - Max.) °F
30 - 60
AFUE (%)
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 2
Motor RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.80
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
4
Power Connection- V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28.75
Crated (in.)
35.5 x 23 x 30.87
Shipping (Lbs.)/Net (Lbs.)
142 / 134
S8X2C100M5PSCSpec sheet · 41 data points
Type
Upflow / Horizontal / Downflow
1st Stage Input BTUH
65,000
1st Stage Capacity BTUH (ICS)
52,300
2nd Stage Input BTUH
100,000
2nd Stage Capacity BTUH (ICS)
80,600
1st Stage Temp. Rise (Min. - Max.) °F
25 - 55
2nd Stage Temp. Rise (Min. - Max.) °F
30 - 60
AFUE (%)
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 2
Motor RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
2.50
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
5 - 45
L.P. Gas Qty. - Drill Size
5 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
5
Power Connection- V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28.75
Crated (in.)
35.5 x 23 x 30.87
Shipping (Lbs.)/Net (Lbs.)
144 / 136
S8X2D120M5PSCSpec sheet · 41 data points
Type
Upflow / Horizontal / Downflow
1st Stage Input BTUH
84,000
1st Stage Capacity BTUH (ICS)
67,800
2nd Stage Input BTUH
120,000
2nd Stage Capacity BTUH (ICS)
98,000
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
2nd Stage Temp. Rise (Min. - Max.) °F
35 - 65
AFUE (%)
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 2
Motor RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
2.15
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 24 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
6 - 45
L.P. Gas Qty. - Drill Size
6 - 56
Gas Valve
Redundant - Two Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
6
Power Connection- V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 24.5 x 28.75
Crated (in.)
35.5 x 26.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
160 / 152

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.