Trane Comfort SpecialistCall (210) 495-7771
Trane · S8X1Trane S8X1 80 Single-Stage Gas FurnaceTrane S8X1 80 Single-Stage Gas Furnace — angle view
Trane · Gas furnaces

Trane S8X1 80 Single-Stage Gas Furnace

Single-stageAlso known as S8X17 models

At a glance

How it runs
Single-stage
Fuel efficiency
Up to 80% AFUE
Heating stages
One
Fuel
gas

What’s built in

  • Nine tap blower motor
  • Self-diagnostic microelectronic controller
  • Heavy steel cabinet
  • Durable silicon nitride hot surface igniter
  • Multi-port, in-shot burners
  • Tubular steel heat exchanger
  • Pre-painted galvanized steel cabinet
  • Insulated cabinet for quiet operation
  • This product was formerly known as the S8X1 Gas Furnace

Every model

ModelHeight (in)Width (in)Depth (in)Energy guide
S8X1A040M3PSC3414.528PDF
S8X1B040M2PSC3417.528PDF
S8X1B060M4PSC3417.528PDF
S8X1B080M4PSC3417.528PDF
S8X1C080M5PSC342128PDF
S8X1C100M5PSC342128PDF
S8X1D120M5PSC3424.528PDF

7 models · 4 columns · swipe the table sideways on a phone

Full spec sheets

7 of 7 models have a full spec sheet below.

S8X1A040M3PSCSpec sheet · 43 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
40,000
Capacity BTUH (ICS)
32,300
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
Direct
CEE Tier
None
Energy Star Rated Region
None
Energy Star Orientation
None
Input-Communication Protocol
24 Volts
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
Integrated Furnace Control
CFM vs. in. w.g.
Motor HP
1/2
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300 / 3162
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
0.30
Inducer Orifice
1.20
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 14 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
2 - 45
L.P. Gas Qty. - Drill Size
2 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
2
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
8.5
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 14.5 x 28.75
Crated (in.)
35.5 x 16.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
102 / 94
S8X1B040M2PSCSpec sheet · 43 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
40,000
Capacity BTUH (ICS)
32,500
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
Direct
CEE Tier
None
Energy Star Rated Region
None
Energy Star Orientation
None
Input-Communication Protocol
24 Volts
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
Integrated Furnace Control
See Fan Performance Table
Motor HP
1/3
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
4.1
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300 / 3225
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
0.30
Inducer Orifice
1.15
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
2 - 45
L.P. Gas Qty. - Drill Size
2 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
2
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
5.6
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
128 / 120
S8X1B060M4PSCSpec sheet · 43 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
60,000
Capacity BTUH (ICS)
48,700
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
Direct
CEE Tier
None
Energy Star Rated Region
None
Energy Star Orientation
None
Input-Communication Protocol
24 Volts
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
Integrated Furnace Control
See Fan Performance Table
Motor HP
3/4
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
9.2
Combustion Fan - Type
SP
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
1.40
Inducer Orifice
1.40
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
3 - 45
L.P. Gas Qty. - Drill Size
3 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
3
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
13.1
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
128 / 120
S8X1B080M4PSCSpec sheet · 43 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
80,000
Capacity BTUH (ICS)
65,100
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
Direct
CEE Tier
None
Energy Star Rated Region
None
Energy Star Orientation
None
Input-Communication Protocol
24 Volts
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
Integrated Furnace Control
See Fan Performance Table
Motor HP
3/4
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
9.2
Combustion Fan - Type
SP
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
1.40
Inducer Orifice
2.15
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
4
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
13.1
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
137 / 129
S8X1C080M5PSCSpec sheet · 43 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
80,000
Capacity BTUH (ICS)
64,700
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
CEE Tier
None
Energy Star Rated Region
None
Energy Star Orientation
None
Input-Communication Protocol
24 Volts
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300 / 2971
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
0.30 / 0.43
Inducer Orifice
1.80
Fiter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
4
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1 / 14.2
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28.75
Crated (in.)
35.5 x 23 x 30.87
Shipping (Lbs.)/Net (Lbs.)
142 / 134
S8X1C100M5PSCSpec sheet · 43 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
100,000
Capacity BTUH (ICS)
80,700
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
CEE Tier
None
Energy Star Rated Region
None
Energy Star Orientation
None
Input-Communication Protocol
24 Volts
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300 / 2680
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
0.33 / 0.58
Inducer Orifice
2.50
Fiter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
5 - 45
L.P. Gas Qty. - Drill Size
5 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
5
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1 / 14.4
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28.75
Crated (in.)
35.5 x 23 x 30.87
Shipping (Lbs.)/Net (Lbs.)
144 / 136
S8X1D120M5PSCSpec sheet · 43 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
120,000
Capacity BTUH (ICS)
98,000
Temp. Rise (Min. - Max.) °F
35 - 65
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
CEE Tier
None
Energy Star Rated Region
None
Energy Star Orientation
None
Input-Communication Protocol
24 Volts
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300 / 3025
Volts/Ph/Hz
120 / 1 / 60
Integrated Furnace Control · FLA
0.33 / 0.57
Inducer Orifice
2.15
Fiter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 24 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
6 - 45
L.P. Gas Qty. - Drill Size
6 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
6
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.1 / 14.4
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 24.5 x 28.75
Crated (in.)
35.5 x 26.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
160 / 152

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More Trane gas furnaces

Call now