RunTru

RunTru · Gas furnaces
RunTru A951X 95-96% AFUE Downflow Furnaces
Photo shows the closest model in the same line.
At a glance
- How it runs
- Single-stage
- Fuel efficiency
- Up to 96% AFUE
- Heating stages
- Single Stage
- Fuel
- Gas
- ENERGY STAR®
- Available on qualifying matches
- Sizes
- 2–5 tons
- Sizes
- 40,000–120,000 BTU/h
Every model
| Model | Tons | Input BTU/h | AFUE | Height (in) | Width (in) | Depth (in) | Energy guide |
|---|---|---|---|---|---|---|---|
| A951X040BD3SAB | 2-3 | 40,000 | 96% | 34 | 17.5 | 28.8 | |
| A951X060BD3SAB | 3 | 60,000 | 96% | 34 | 17.5 | 28.8 | |
| A951X080BD4SAB | 4 | 80,000 | 95% | 34 | 17.5 | 28.8 | |
| A951X100CD5SAB | 5 | 100,000 | 96% | 34 | 21 | 28.8 | |
| A951X120DD5SAB | 5 | 120,000 | 95% | 34 | 24.5 | 28.8 |
5 models · 7 columns · swipe the table sideways on a phone
Full spec sheets
5 of 5 models have a full spec sheet below.
A951X040BD3SAB2-3 ton · 37 data points
- Type
- Downflow
- Input BTUH
- 40,000
- Capacity BTUH (ICS)
- 38,900
- Temp. Rise (Min.-Max.)
- 30 - 60
- AFUE (%)
- 96.0
- Return Air Temp. (Min. - Max.)
- 45°F - 80°F
- Blower Drive
- DIRECT
- Diameter / Width (In.)
- 11 X 8
- No. Used
- 1
- Speeds (No.)
- 9
- CFM vs. in. w.g
- See Fan Performance Table
- Motor HP
- 1/2
- RPM
- 1075
- Volts/Ph/Hz
- 120 / 1 / 60
- FLA
- 6.4
- Combustion Fan / Type
- Centrifugal
- Drive / No. Speeds
- Direct - 1
- Motor HP / RPM
- 3300
- Filter / Furnished?
- No
- Type recommended
- High Velocity
- Hi Vel. (No.-Size-Thk.)
- 1 - 16 X 25 - 1 in.
- Vent Pipe Diameter / Min (in.)
- 2 Round
- Type / Fired
- 409 Stainless Steel
- Unfired
- 29–4C Stainless Steel
- Gauge (Fired)
- 20
- Nat. Gas Qty. / Drill Size
- 2- 45
- Propane Gas Qty. / Drill Size
- 2- 56
- Gas Valve
- Redundant - One Stage
- Burners / Type
- Multiport Inshot
- Number
- 2
- Power Conn. / V/Ph/Hz
- 120 / 1 / 60
- Ampacity (In Amps)
- 10.3
- Max. Overcurrent Protection (Amps)
- 15
- Pipe Conn. Size (in.)
- 1/2
- Uncrated (In.)
- 34 x 17-1/2 x 28–3/4
- Crated (In.)
- 35-1/2 x 19-1/2 x 30-7/8
- Shipping (Lbs.)/Net (Lbs.)
- 122/114
A951X060BD3SAB3 ton · 37 data points
- Type
- Downflow
- Input BTUH
- 60,000
- Capacity BTUH (ICS)
- 57,600
- Temp. Rise (Min.-Max.)
- 35 - 65
- AFUE (%)
- 96.0
- Return Air Temp. (Min. - Max.)
- 45°F - 80°F
- Blower Drive
- DIRECT
- Diameter / Width (In.)
- 11 X 8
- No. Used
- 1
- Speeds (No.)
- 9
- CFM vs. in. w.g
- See Fan Performance Table
- Motor HP
- 1/2
- RPM
- 1075
- Volts/Ph/Hz
- 120 / 1 / 60
- FLA
- 6.4
- Combustion Fan / Type
- Centrifugal
- Drive / No. Speeds
- Direct - 1
- Motor HP / RPM
- 3300
- Filter / Furnished?
- No
- Type recommended
- High Velocity
- Hi Vel. (No.-Size-Thk.)
- 1 - 16 X 25 - 1 in.
- Vent Pipe Diameter / Min (in.)
- 2 Round
- Type / Fired
- 409 Stainless Steel
- Unfired
- 29–4C Stainless Steel
- Gauge (Fired)
- 20
- Nat. Gas Qty. / Drill Size
- 3 - 45
- Propane Gas Qty. / Drill Size
- 3 - 56
- Gas Valve
- Redundant - One Stage
- Burners / Type
- Multiport Inshot
- Number
- 3
- Power Conn. / V/Ph/Hz
- 120 / 1 / 60
- Ampacity (In Amps)
- 10.3
- Max. Overcurrent Protection (Amps)
- 15
- Pipe Conn. Size (in.)
- 1/2
- Uncrated (In.)
- 34 x 17-1/2 x 28–3/4
- Crated (In.)
- 35-1/2 x 19-1/2 x 30-7/8
- Shipping (Lbs.)/Net (Lbs.)
- 127/119
A951X080BD4SAB4 ton · 36 data points
- Type
- Downflow
- Input BTUH
- 80,000
- Capacity BTUH (ICS)
- 76,900
- Temp. Rise (Min.-Max.)
- 45 - 75
- AFUE (%)
- 95.0
- Return Air Temp. (Min. - Max.)
- 45°F - 80°F
- Blower Drive
- DIRECT
- Diameter / Width (In.)
- 11 X 8
- No. Used
- 1
- Speeds (No.)
- 9
- Motor HP
- 3/4
- RPM
- 1075
- Volts/Ph/Hz
- 120 / 1 / 60
- FLA
- 9.3
- Combustion Fan / Type
- Centrifugal
- Drive / No. Speeds
- Direct - 1
- Motor HP / RPM
- 3300
- Filter / Furnished?
- No
- Type recommended
- High Velocity
- Hi Vel. (No.-Size-Thk.)
- 1 - 16 X 25 - 1 in.
- Vent Pipe Diameter / Min (in.)
- 2 Round
- Type / Fired
- 409 Stainless Steel
- Unfired
- 29–4C Stainless Steel
- Gauge (Fired)
- 20
- Nat. Gas Qty. / Drill Size
- 4 - 45
- Propane Gas Qty. / Drill Size
- 4- 56
- GAS VALVE
- Redundant - One Stage
- Burners / Type
- Multiport Inshot
- Number
- 4
- Power Conn. / V/Ph/Hz
- 120 / 1 / 60
- Ampacity (In Amps)
- 13.9
- Max. Overcurrent Protection (Amps)
- 15
- Pipe Conn. Size (in.)
- 1/2
- Uncrated (In.)
- 34 x 17-1/2 x 28–3/4
- Crated (In.)
- 35-1/2 x 19-1/2 x 30-7/8
- Shipping (Lbs.)/Net (Lbs.)
- 135/127
A951X100CD5SAB5 ton · 36 data points
- Type
- Downflow
- Input BTUH
- 100,000
- Capacity BTUH (ICS)
- 96,800
- Temp. Rise (Min.-Max.)
- 40 - 70
- AFUE (%)
- 96.0
- Return Air Temp. (Min. - Max.)
- 45°F - 80°F
- Blower Drive
- DIRECT
- Diameter / Width (In.)
- 11 X 10
- No. Used
- 1
- Speeds (No.)
- 9
- Motor HP
- 1
- RPM
- 1075
- Volts/Ph/Hz
- 120 / 1 / 60
- FLA
- 10.6
- Combustion Fan / Type
- Centrifugal
- Drive / No. Speeds
- Direct - 1
- Motor HP / RPM
- 3300
- Filter / Furnished?
- No
- Type recommended
- High Velocity
- Hi Vel. (No.-Size-Thk.)
- 1 - 20 X 25 - 1 in.
- Vent Pipe Diameter / Min (in.)
- 2 Round
- Type / Fired
- 409 Stainless Steel
- Unfired
- 29–4C Stainless Steel
- Gauge (Fired)
- 20
- Nat. Gas Qty. / Drill Size
- 5 - 45
- Propane Gas Qty. / Drill Size
- 5- 56
- GAS VALVE
- Redundant - One Stage
- Burners / Type
- Multiport Inshot
- Number
- 5
- Power Conn. / V/Ph/Hz
- 120 / 1 / 60
- Ampacity (In Amps)
- 14.1
- Max. Overcurrent Protection (Amps)
- 15
- Pipe Conn. Size (in.)
- 1/2
- Uncrated (In.)
- 34 x 21 x 28–3/4
- Crated (In.)
- 35-1/2 x 23 x 30-7/8
- Shipping (Lbs.)/Net (Lbs.)
- 155/145
A951X120DD5SAB5 ton · 36 data points
- Type
- Downflow
- Input BTUH
- 120,000
- Capacity BTUH (ICS)
- 115,500
- Temp. Rise (Min.-Max.)
- 45-75
- AFUE (%)
- 95.0
- Return Air Temp. (Min. - Max.)
- 45°F - 80°F
- Blower Drive
- DIRECT
- Diameter / Width (In.)
- 11 X 10
- No. Used
- 1
- Speeds (No.)
- 9
- Motor HP
- 1
- RPM
- 1075
- Volts/Ph/Hz
- 120 / 1 / 60
- FLA
- 10.6
- Combustion Fan / Type
- Centrifugal
- Drive / No. Speeds
- Direct - 1
- Motor HP / RPM
- 3300
- Filter / Furnished?
- No
- Type recommended
- High Velocity
- Hi Vel. (No.-Size-Thk.)
- 1 - 24 X 25 - 1 in.
- Vent Pipe Diameter / Min (in.)
- 3 Round
- Type / Fired
- 409 Stainless Steel
- Unfired
- 29–4C Stainless Steel
- Gauge (Fired)
- 20
- Nat. Gas Qty. / Drill Size
- 6 - 45
- Propane Gas Qty. / Drill Size
- 6- 56
- GAS VALVE
- Redundant - One Stage
- Burners / Type
- Multiport Inshot
- Number
- 6
- Power Conn. / V/Ph/Hz
- 120 / 1 / 60
- Ampacity (In Amps)
- 14.1
- Max. Overcurrent Protection (Amps)
- 15
- Pipe Conn. Size (in.)
- 1/2
- Uncrated (In.)
- 34 x 24-1/2 x 28–3/4
- Crated (In.)
- 35-1/2 x 26-1/2 x 30-7/8
- Shipping (Lbs.)/Net (Lbs.)
- 167/156
Source documents
Why buy it from Cowboy’s
Sized for your house, installed by the people who answer the phone
We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.
Call (210) 495-7771