Trane Comfort SpecialistCall (210) 495-7771
RunTruRunTru A801X Furnace
RunTru · Gas furnaces

RunTru A801X Furnace

Single-stage8 models

At a glance

How it runs
Single-stage
Fuel efficiency
Up to 80% AFUE
Heating stages
Single-stage
Fuel
Gas
Sizes
26,000–120,000 BTU/h

Every model

ModelInput BTU/hAFUEHeight (in)Width (in)Depth (in)Energy guide
A801X026AM2SCA26,00080%3414.528.8—
A801X040AM3SDA40,00080%3414.528.8PDF
A801X040BM2SDA40,00080%3417.528.8PDF
A801X060BM4SDA60,00080%3417.528.8PDF
A801X080BM4SDA80,00080%3417.528.8PDF
A801X080CM5SDA80,00080%342128.8PDF
A801X100CM5SDA100,00080%342128.8PDF
A801X120DM5SDA120,00080%3424.528.8PDF

8 models · 6 columns · swipe the table sideways on a phone

Full spec sheets

7 of 8 models have a full spec sheet below.

A801X040AM3SDA40,000 BTU/h · 38 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
40,000
Capacity BTUH (ICS)
32,300
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1/2
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
6.4
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.20
Fiter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 14 X 25 - 1 in.
Vent Pipe Diamter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
2 - 45
L.P. Gas Qty. - Drill Size
2 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
2
Power Connection. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
8.5
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 14.5 x 28.75
Crated (in.)
35.5 x 16.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
102 / 94
A801X040BM2SDA40,000 BTU/h · 38 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
40,000
Capacity BTUH (ICS)
32,500
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1/3
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
4.1
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.15
Fiter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diamter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
2 - 45
L.P. Gas Qty. - Drill Size
2 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
2
Power Connection. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
5.6
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
128 / 120
A801X060BM4SDA60,000 BTU/h · 38 data points
Type
Upflow / Horizontal / Downflow
Input BTUH
80,000
Capacity BTUH (ICS)
48,700
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
3/4
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
9.2
Combustion Fan - Type
SP
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.40
Fiter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diamter - Min. (in.)
4 Round
Heat Exchanger - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
3 - 45
L.P. Gas Qty. - Drill Size
3 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
3
Power Connection. - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
13.1
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
132 / 124
A801X080BM4SDA80,000 BTU/h · 38 data points
Type
Downflow
Input BTUH
80,000
Capacity BTUH (ICS)
65,100
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 8
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
3/4
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
9.2
Combustion Fan - Type
SP
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
2.15
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchnager - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
4
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
13.1
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 17.5 x 28.75
Crated (in.)
35.5 x 19.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
137 / 129
A801X080CM5SDA80,000 BTU/h · 38 data points
Type
Downflow
Input BTUH
80,000
Capacity BTUH (ICS)
64,700
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
1.80
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchnager - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
4 - 45
L.P. Gas Qty. - Drill Size
4 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
4
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.2
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28.75
Crated (in.)
35.5 x 23 x 30.87
Shipping (Lbs.)/Net (Lbs.)
142 / 134
A801X100CM5SDA100,000 BTU/h · 38 data points
Type
Downflow
Input BTUH
100,000
Capacity BTUH (ICS)
80,700
Temp. Rise (Min. - Max.) °F
30 - 60
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
2.50
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchnager - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
5 - 45
L.P. Gas Qty. - Drill Size
5 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
5
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.4
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 21 x 28.75
Crated (in.)
35.5 x 23 x 30.87
Shipping (Lbs.)/Net (Lbs.)
144 / 136
A801X120DM5SDA120,000 BTU/h · 38 data points
Type
Downflow
Input BTUH
120,000
Capacity BTUH (ICS)
98,000
Temp. Rise (Min. - Max.) °F
35 - 65
AFUE - Rating
80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F
Blower Drive
DIRECT
Diameter - Width (in.)
11 X 11
No. Used
1
Speeds (No.)
CTM - 9
CFM vs. in. w.g
See Fan Performance Table
Motor HP
1
R.P.M
1050
Volts / Ph / Hz
120 / 1 / 60
FLA
10.9
Combustion Fan - Type
PSC
Drive - No. Speeds
Direct - 1
Motor RPM
3300
Volts/Ph/Hz
120 / 1 / 60
Inducer Orifice
2.15
Filter - Furnished?
No
Type Recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 24 X 25 - 1 in.
Vent Pipe Diameter - Min. (in.)
4 Round
Heat Exchnager - Type
Aluminized Steel
Gauge (Fired)
20 - 19
Nat. Gas Qty. - Drill Size
6 - 45
L.P. Gas Qty. - Drill Size
6 - 56
Gas Valve
Redundant - Single Stage
Pilot Safety Device - Type
120 V SiNi Igniter
Burners - Qty
6
Power Connection - V/Ph/HZ
120 / 1 / 60
Ampacity (Amps)
14.4
Max. Overcurrent Protection (Amps)
15
Pipe Connection Size (in.)
1/2
Uncrated (in.)
34 x 24.5 x 28.75
Crated (in.)
35.5 x 26.5 x 30.87
Shipping (Lbs.)/Net (Lbs.)
160 / 152

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More RunTru gas furnaces

Call now