Trane Comfort SpecialistCall (210) 495-7771
TraneTrane COMFORT-COIL
Trane · Coils

Trane COMFORT-COIL

17 models

Availability varies by market

At a glance

Sizes
1.5–3 tons
Refrigerant
R-454B

What’s built in

  • All aluminum construction
  • Leak tested
  • Cleaned coils
  • Factory installed TXV
  • Foil backed insulation
  • Noncorrosive drain pan
  • Painted finish

Every model

ModelTonsHeight (in)Width (in)Depth (in)Refrigerant
5PXCA001AS3HAA1.5 - 2.017.514.521.5R-454B
5PXCA002AS3HAA1.5 - 3.022.514.521.5R-454B
5PXCB003AS3HAA1.5 - 3.017.517.521.5R-454B
5PXCB004AS3HAA2.0 - 3.522.517.521.5R-454B
5PXCB006AS3HAA2.0 - 5.026.917.521.5R-454B
5PXCBD03AS3HDA1.5 - 3.017.517.521.5R-454B
5PXCBD04AS3HDA2.0 - 3.522.517.521.5R-454B
5PXCBD06AS3HDA2.0 - 5.026.917.521.5R-454B
5PXCC005AS3HAA2.0 - 4.022.52121.5R-454B
5PXCC007AS3HAA3.0 - 5.026.92121.5R-454B
5PXCC009AS3HAA3.0 - 5.030.82121.5R-454B
5PXCCD05AS3HDA2.0 - 3.522.52121.5R-454B
5PXCCD07AS3HDA3.0 - 5.026.92121.5R-454B
5PXCCD09AS3HDA3.0 - 5.030.82121.5R-454B
5PXCD008AS3HAA3.0 - 5.026.924.521.5R-454B
5PXCD010AS3HAA3.0 - 5.030.824.521.5R-454B
5PXCDD10AS3HDA3.0 - 5.030.824.521.5R-454B

17 models · 6 columns · swipe the table sideways on a phone

Full spec sheets

17 of 17 models have a full spec sheet below.

5PXCA001AS3HAA1.5 - 2.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
1.5 to 2.0
Rows / F.P.I
2 / 20
Face Area (sq.ft.)
3.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCA002AS3HAA1.5 - 3.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
1.5 to 3.0
Rows / F.P.I
2 / 20
Face Area (sq.ft.)
4.5
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCB003AS3HAA1.5 - 3.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
1.5 to 3.0
Rows / F.P.I
3 / 14
Face Area (sq.ft.)
3.5
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCB004AS3HAA2.0 - 3.5 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
2.0 to 3.5
Rows / F.P.I
3 / 12
Face Area (sq.ft.)
5.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCB006AS3HAA2.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
2.0 to 5.0
Rows / F.P.I
3 / 14
Face Area (sq.ft.)
6.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCBD03AS3HDA1.5 - 3.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
1.5 to 3.0
Rows / F.P.I
3 / 14
Face Area (sq.ft.)
3.5
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCBD04AS3HDA2.0 - 3.5 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
2.0 to 3.5
Rows / F.P.I
3 / 12
Face Area (sq.ft.)
5.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCBD06AS3HDA2.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
2.0 to 5.0
Rows / F.P.I
3 / 14
Face Area (sq.ft.)
6.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCC005AS3HAA2.0 - 4.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
2.0 to 4.0
Rows / F.P.I
3 / 12
Face Area (sq.ft.)
5.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCC007AS3HAA3.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
3.0 to 5.0
Rows / F.P.I
3 / 14
Face Area (sq.ft.)
6.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCC009AS3HAA3.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
3.0 to 5.0
Rows / F.P.I
3 / 16
Face Area (sq.ft.)
7.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCCD05AS3HDA2.0 - 3.5 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
2.0 to 3.5
Rows / F.P.I
3 / 12
Face Area (sq.ft.)
5.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCCD07AS3HDA3.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
3.0 to 5.0
Rows / F.P.I
3 / 14
Face Area (sq.ft.)
6.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCCD09AS3HDA3.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
3.0 to 5.0
Rows / F.P.I
3 / 16
Face Area (sq.ft.)
7.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCD008AS3HAA3.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
3.0 to 5.0
Rows / F.P.I
3 / 14
Face Area (sq.ft.)
6.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCD010AS3HAA3.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
3.0 to 5.0
Rows / F.P.I
3 / 16
Face Area (sq.ft.)
7.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing
5PXCDD10AS3HDA3.0 - 5.0 ton · 9 data points
Indoor coil- Type
Plate Fin
Cooling Capacity (Tons)
3.0 to 5.0
Rows / F.P.I
3 / 16
Face Area (sq.ft.)
7.0
Tube Size
3/8
Refrigerant Control
Non-Bleed TXV
Internal check valve
Yes
Drain Conn. Size (in.)
3/4
Duct Connections
See Outline Drawing

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More Trane coils