Trane Comfort SpecialistCall (210) 495-7771
TraneTrane 16 Single-Stage Heat PumpTrane 16 Single-Stage Heat Pump — angle view
Trane · Heat pumps

Trane 16 Single-Stage Heat Pump

Single-stage7 models

At a glance

How it runs
Single-stage
Cooling efficiency
Up to 17 SEER2
Heating efficiency
Up to 8.5 HSPF2
Compressor stages
One
Sizes
1.5–5 tons
Refrigerant
R-454B

What’s built in

  • Next-generation R-454B refrigerant
  • Low global warming potential (GWP)
  • Climatuff® compressor
  • All-aluminum Spine Fin™ coil
  • Integrated fan system for quiet operation
  • DuraTuff™ Rustproof Basepan

Every model

ModelTonsHeight (in)Width (in)Depth (in)RefrigerantEnergy guide
5TWR6018A1000A1.532.832.629.8R-454BPDF
5TWR6024A1000A232.832.629.8R-454BPDF
5TWR6030A1000A2.532.832.629.8R-454BPDF
5TWR6036A1000A333.137.334.3R-454BPDF
5TWR6042A1000A3.545.137.334.3R-454BPDF
5TWR6048A1000A445.137.334.3R-454BPDF
5TWR6060A1000A545.137.334.3R-454BPDF

7 models · 6 columns · swipe the table sideways on a phone

Full spec sheets

7 of 7 models have a full spec sheet below.

5TWR6018A1000A1.5 ton · 31 data points
Power Conns. / V/Ph/Hz
208/230/1/60
Min. BRCH. CIR. Ampacity
12
BR. CIR. PROT. RTG. / Max. (Amps)
20
Compressor
CLIMATUFF® - SCROLL
No. Used / No. Stages
1–1
Volts/Ph/Hz
208/230/1/60
RL Amps / LR Amps
7.8 - 47.5
Start Components
NO (Uses BAYSKT263)
Insulation/Sound Blanket
NO
Compressor Heat
NO
Outdoor Fan
PROPELLER
DIA. (in.) Used
23 – 1
Type Drive / No. Speeds
DIRECT – 1
CFM @ 0.0 (in.) W.G
2980
No. Motors / HP
1 – 1/8
Motor Speed R.P.M
850
Factory Installed · Volts/Ph/Hz
208/230/1/60
F.L. Amps
0.77
Outdoor Coil / Type
SPINE FIN™
Rows / F.P.I
1 – 24
Face Area (Sq. Ft.)
18.75
Tube Size (in.)
3/8
Refrigerant Control
Expansion Valve
lb. / R-454B (O.D. Unit)
4 lb, 12 oz
Factory Supplied
YES
Line Size / (in.) O.D. Gas
3/4
Line Size / (in.) O.D. Liq
5/16
Subcooling
9°F
Crated (in.)
38.1 x 30 x 33
Shipping (lb.)
208
Net (lb.)
174
5TWR6024A1000A2 ton · 31 data points
Power Conns. / V/Ph/Hz
208/230/1/60
Min. BRCH. CIR. Ampacity
13
BR. CIR. PROT. RTG. / Max. (Amps)
20
Compressor
CLIMATUFF® - SCROLL
No. Used / No. Stages
1–1
Volts/Ph/Hz
208/230/1/60
RL Amps / LR Amps
9.1 - 75.9
Start Components
NO (Uses BAYSKT263)
Insulation/Sound Blanket
NO
Compressor Heat
NO
Outdoor Fan
PROPELLER
DIA. (in.) Used
23 – 1
Type Drive / No. Speeds
DIRECT – 1
CFM @ 0.0 (in.) W.G
2980
No. Motors / HP
1 – 1/8
Motor Speed R.P.M
850
Factory Installed · Volts/Ph/Hz
208/230/1/60
F.L. Amps
0.77
Outdoor Coil / Type
SPINE FIN™
Rows / F.P.I
1 – 24
Face Area (Sq. Ft.)
18.75
Tube Size (in.)
3/8
Refrigerant Control
Expansion Valve
lb. / R-454B (O.D. Unit)
4 lb, 10 oz
Factory Supplied
YES
Line Size / (in.) O.D. Gas
3/4
Line Size / (in.) O.D. Liq
5/16
Subcooling
12°F
Crated (in.)
38.1 x 30 x 33
Shipping (lb.)
208
Net (lb.)
174
5TWR6030A1000A2.5 ton · 31 data points
Power Conns. / V/Ph/Hz
208/230/1/60
Min. BRCH. CIR. Ampacity
16
BR. CIR. PROT. RTG. / Max. (Amps)
25
Compressor
CLIMATUFF® - SCROLL
No. Used / No. Stages
1–1
Volts/Ph/Hz
208/230/1/60
RL Amps / LR Amps
10.4 - 71.0
Start Components
NO (Uses BAYSKT263)
Insulation/Sound Blanket
NO
Compressor Heat
NO
Outdoor Fan
PROPELLER
DIA. (in.) Used
23 – 1
Type Drive / No. Speeds
DIRECT – 1
CFM @ 0.0 (in.) W.G
2820
No. Motors / HP
1 – 1/8
Motor Speed R.P.M
850
Factory Installed · Volts/Ph/Hz
208/230/1/60
F.L. Amps
0.77
Outdoor Coil / Type
SPINE FIN™
Rows / F.P.I
1 – 24
Face Area (Sq. Ft.)
18.75
Tube Size (in.)
3/8
Refrigerant Control
Expansion Valve
lb. / R-454B (O.D. Unit)
4 lb, 10 oz
Factory Supplied
YES
Line Size / (in.) O.D. Gas
3/4
Line Size / (in.) O.D. Liq
5/16
Subcooling
12°F
Crated (in.)
38.1 x 30 x 33
Shipping (lb.)
208
Net (lb.)
174
5TWR6036A1000A3 ton · 31 data points
Power Conns. / V/Ph/Hz
208/230/1/60
Min. BRCH. CIR. Ampacity
19
BR. CIR. PROT. RTG. / Max. (Amps)
30
Compressor
CLIMATUFF® - SCROLL
No. Used / No. Stages
1–1
Volts/Ph/Hz
208/230/1/60
RL Amps / LR Amps
13.5 - 75
Start Components
NO (Uses BAYSKT263)
Insulation/Sound Blanket
NO
Compressor Heat
NO
Outdoor Fan
PROPELLER
DIA. (in.) Used
27.5 – 1
Type Drive / No. Speeds
DIRECT – 1
CFM @ 0.0 (in.) W.G
4230
No. Motors / HP
1 – 1/8
Motor Speed R.P.M
850
Factory Installed · Volts/Ph/Hz
200/230/1/60
F.L. Amps
0.64
Outdoor Coil / Type
SPINE FIN™
Rows / F.P.I
1 – 24
Face Area (Sq. Ft.)
24
Tube Size (in.)
3/8
Refrigerant Control
Expansion Valve
lb. / R-454B (O.D. Unit)
5 lb, 10 oz
Factory Supplied
YES
Line Size / (in.) O.D. Gas
3/4
Line Size / (in.) O.D. Liq
5/16
Subcooling
10°F
Crated (in.)
38.5 x 35 x 37.9
Shipping (lb.)
256
Net (lb.)
222
5TWR6042A1000A3.5 ton · 31 data points
Power Conns. / V/Ph/Hz
208/230/1/60
Min. BRCH. CIR. Ampacity
24
BR. CIR. PROT. RTG. / Max. (Amps)
40
Compressor
CLIMATUFF® - SCROLL
No. Used / No. Stages
1–1
Volts/Ph/Hz
208/230/1/60
RL Amps / LR Amps
16.9 – 104.7
Start Components
NO (Uses BAYSKT263)
Insulation/Sound Blanket
NO
Compressor Heat
NO
Outdoor Fan
PROPELLER
DIA. (in.) Used
27.5 – 1
Type Drive / No. Speeds
DIRECT – 1
CFM @ 0.0 (in.) W.G
4992
No. Motors / HP
1 – 1/3
Motor Speed R.P.M
850
Factory Installed · Volts/Ph/Hz
200/230/1/60
F.L. Amps
2.80
Outdoor Coil / Type
SPINE FIN™
Rows / F.P.I
2 - 24
Face Area (Sq. Ft.)
30.8
Tube Size (in.)
3/8
Refrigerant Control
Expansion Valve
lb. / R-454B (O.D. Unit)
7 lb, 14 oz
Factory Supplied
YES
Line Size / (in.) O.D. Gas
7/8
Line Size / (in.) O.D. Liq
5/16
Subcooling
10°F
Crated (in.)
50.5 x 35 x 37.9
Shipping (lb.)
301
Net (lb.)
251
5TWR6048A1000A4 ton · 31 data points
Power Conns. / V/Ph/Hz
208/230/1/60
Min. BRCH. CIR. Ampacity
25
BR. CIR. PROT. RTG. / Max. (Amps)
40
Compressor
CLIMATUFF® - SCROLL
No. Used / No. Stages
1–1
Volts/Ph/Hz
208/230/1/60
RL Amps / LR Amps
18.1 – 95.0
Start Components
NO (Uses BAYSKT263)
Insulation/Sound Blanket
NO
Compressor Heat
NO
Outdoor Fan
PROPELLER
DIA. (in.) Used
27.5 – 1
Type Drive / No. Speeds
DIRECT – 1
CFM @ 0.0 (in.) W.G
4992
No. Motors / HP
1 – 1/3
Motor Speed R.P.M
850
Factory Installed · Volts/Ph/Hz
208/230/1/60
F.L. Amps
2.80
Outdoor Coil / Type
SPINE FIN™
Rows / F.P.I
2 - 24
Face Area (Sq. Ft.)
30.8
Tube Size (in.)
3/8
Refrigerant Control
Expansion Valve
lb. / R-454B (O.D. Unit)
8 lb, 9 oz
Factory Supplied
YES
Line Size / (in.) O.D. Gas
7/8
Line Size / (in.) O.D. Liq
5/16
Subcooling
10°F
Crated (in.)
50.5 x 35 x 37.9
Shipping (lb.)
301
Net (lb.)
251
5TWR6060A1000A5 ton · 31 data points
Power Conns. / V/Ph/Hz
208/230/1/60
Min. BRCH. CIR. Ampacity
33
BR. CIR. PROT. RTG. / Max. (Amps)
50
Compressor
CLIMATUFF® - SCROLL
No. Used / No. Stages
1–1
Volts/Ph/Hz
208/230/1/60
RL Amps / LR Amps
22.3 - 136.6
Start Components
NO (Uses BAYSKT263)
Insulation/Sound Blanket
NO
Compressor Heat
NO
Outdoor Fan
PROPELLER
DIA. (in.) Used
27.5 – 1
Type Drive / No. Speeds
DIRECT – 1
CFM @ 0.0 (in.) W.G
4992
No. Motors / HP
1 – 1/3
Motor Speed R.P.M
850
Factory Installed · Volts/Ph/Hz
208/230/1/60
F.L. Amps
2.80
Outdoor Coil / Type
SPINE FIN™
Rows / F.P.I
2 - 24
Face Area (Sq. Ft.)
30.8
Tube Size (in.)
3/8
Refrigerant Control
Expansion Valve
lb. / R-454B (O.D. Unit)
8 lb, 6 oz
Factory Supplied
YES
Line Size / (in.) O.D. Gas
7/8
Line Size / (in.) O.D. Liq
5/16
Subcooling
10°F
Crated (in.)
50.5 x 35 x 37.9
Shipping (lb.)
301
Net (lb.)
251

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More Trane heat pumps

Call now