Trane Comfort SpecialistCall (210) 495-7771
RunTruRunTru A5AHC Air Handler
RunTru · Air handlers

RunTru A5AHC Air Handler

6 models

Photo shows the closest model in the same line.

At a glance

Sizes
18–42 tons
Refrigerant
R-454B

Every model

ModelTonsHeight (in)Width (in)Depth (in)RefrigerantMotorMetering
A5AHC002A1B30A18-2445.118.521.1R-454BConstant TorqueTXV
A5AHC003A1B30A18-3046.818.521.1R-454BConstant TorqueTXV
A5AHC004A1B30A24-3651.818.521.1R-454BConstant TorqueTXV
A5AHC005A1D30A36-4851.423.521.1R-454BConstant TorqueTXV
A5AHC006A1D30A36-4857.423.521.1R-454BConstant TorqueTXV
A5AHC007A1D30A42-6057.423.521.1R-454BConstant TorqueTXV

6 models · 8 columns · swipe the table sideways on a phone

Full spec sheets

6 of 6 models have a full spec sheet below.

A5AHC002A1B30A18-24 ton · 26 data points
Application Configuration
4-Way
Rated Capacity Range (BTUH)
18K - 24K
System Control Type
24V
Power Conn. - V/Ph/Hz
208-230/1/60
Max Breaker Size, Without
15
Max Breaker Size, With Electric
60
Coil Type
All-Aluminum Plate Fin
Refrigerant Type
R-454B
Refrigerant Control
TXV
Refrigerant Line Connection - Gas
7/8
Refrigerant Line Connection
3/8
Blower Type
Direct Drive Centrifugal
Configuration
Blow Through
Dimensions (Diameter x Width
11 x 8
Motor Type
Constant Torque
Nominal CFM
600
Speed (RPM)
1050
Volts/Ph/Hz
208-230/1/60
Full Load Amps
2.6
Filter Rack (Yes, No)
No
Supply (in.)
12.15 x 16.50
Return (in.)
18.75 x 16.75
Drain Conn. Size (in.)
3/4 NPT
Uncrated (in.)
45-1/8 x 18-1/2 x 21-1/8
Crated (in.)
46-1/2 x 22-1/2 x 25-1/2
Weight - Shipping/Net (lbs.)
116/110
A5AHC003A1B30A18-30 ton · 26 data points
Application Configuration
4-Way
Rated Capacity Range (BTUH)
18K - 30K
System Control Type
24V
Power Conn. - V/Ph/Hz
208-230/1/60
Max Breaker Size, Without
15
Max Breaker Size, With Electric
60
Coil Type
All-Aluminum Plate Fin
Refrigerant Type
R-454B
Refrigerant Control
TXV
Refrigerant Line Connection - Gas
7/8
Refrigerant Line Connection
3/8
Blower Type
Direct Drive Centrifugal
Configuration
Blow Through
Dimensions (Diameter x Width
11 x 8
Motor Type
Constant Torque
Nominal CFM
800
Speed (RPM)
1050
Volts/Ph/Hz
208-230/1/60
Full Load Amps
3.9
Filter Rack (Yes, No)
No
Supply (in.)
12.15 x 16.50
Return (in.)
18.75 x 16.75
Drain Conn. Size (in.)
3/4 NPT
Uncrated (in.)
46-3/4 x 18-1/2 x 21-1/8
Crated (in.)
48-1/4 x 22-1/2 x 25-1/2
Weight - Shipping/Net (lbs.)
126/117
A5AHC004A1B30A24-36 ton · 26 data points
Application Configuration
4-Way
Rated Capacity Range (BTUH)
24K - 36K
System Control Type
24V
Power Conn. - V/Ph/Hz
208-230/1/60
Max Breaker Size, Without
15
Max Breaker Size, With Electric
60
Coil Type
All-Aluminum Plate Fin
Refrigerant Type
R-454B
Refrigerant Control
TXV
Refrigerant Line Connection - Gas
7/8
Refrigerant Line Connection
3/8
Blower Type
Direct Drive Centrifugal
Configuration
Blow Through
Dimensions (Diameter x Width
11 x 8
Motor Type
Constant Torque
Nominal CFM
1200
Speed (RPM)
1050
Volts/Ph/Hz
208-230/1/60
Full Load Amps
3.9
Filter Rack (Yes, No)
No
Supply (in.)
12.15 x 16.50
Return (in.)
18.75 x 16.75
Drain Conn. Size (in.)
3/4 NPT
Uncrated (in.)
51-3/4 x 18-1/2 x 21-1/8
Crated (in.)
53-1/4 x 22-1/2 x 25-1/2
Weight - Shipping/Net (lbs.)
138/132
A5AHC005A1D30A36-48 ton · 27 data points
Family Description
R-454B Convertible Air
Application Configuration
4-Way
Rated Capacity Range (BTUH)
36K - 48K
System Control Type
24V
Power Conn. - V/Ph/Hz
208-230/1/60
Max Breaker Size, Without Electric Heater
15
Max Breaker Size, With Electric Heater
60
Coil Type
All-Aluminum Plate Fin
Refrigerant Type
R-454B
Refrigerant Control
TXV
Refrigerant Line Connection - Gas (in.)
7/8
Refrigerant Line Connection - Liquid (in.)
3/8
Blower Type
Direct Drive Centrifugal
Configuration
Blow Through
Dimensions (Diameter x Width (in.))
11 x 8
Motor Type
Constant Torque
Nominal CFM
1400
Speed (RPM)
1050
Volts/Ph/Hz
208-230/1/60
Full Load Amps
3.9
Filter Rack (Yes, No)
No
Supply (in.)
12.15 x 21.50
Return (in.)
18.75 x 21.75
Drain Conn. Size (in.)
3/4 NPT
Uncrated (in.)
51-3/8 x 23-1/2 x 21-1/8
Crated (in.)
52-3/4 x 27-1/2 x 25-1/2
Weight - Shipping/Net (lbs.)
145/138
A5AHC006A1D30A36-48 ton · 27 data points
Family Description
R-454B Convertible Air
Application Configuration
4-Way
Rated Capacity Range (BTUH)
36K - 48K
System Control Type
24V
Power Conn. - V/Ph/Hz
208-230/1/60
Max Breaker Size, Without Electric Heater
15
Max Breaker Size, With Electric Heater
60
Coil Type
All-Aluminum Plate Fin
Refrigerant Type
R-454B
Refrigerant Control
TXV
Refrigerant Line Connection - Gas (in.)
7/8
Refrigerant Line Connection - Liquid (in.)
3/8
Blower Type
Direct Drive Centrifugal
Configuration
Blow Through
Dimensions (Diameter x Width (in.))
11 x 8
Motor Type
Constant Torque
Nominal CFM
1600
Speed (RPM)
1050
Volts/Ph/Hz
208-230/1/60
Full Load Amps
6.0
Filter Rack (Yes, No)
No
Supply (in.)
12.15 x 21.50
Return (in.)
18.75 x 21.75
Drain Conn. Size (in.)
3/4 NPT
Uncrated (in.)
51-3/8 x 23-1/2 x 21-1/8
Crated (in.)
52-3/4 x 27-1/2 x 25-1/2
Weight - Shipping/Net (lbs.)
155/144
A5AHC007A1D30A42-60 ton · 27 data points
Family Description
R-454B Convertible Air
Application Configuration
4-Way
Rated Capacity Range (BTUH)
42K - 60K
System Control Type
24V
Power Conn. - V/Ph/Hz
208-230/1/60
Max Breaker Size, Without Electric Heater
15
Max Breaker Size, With Electric Heater
60
Coil Type
All-Aluminum Plate Fin
Refrigerant Type
R-454B
Refrigerant Control
TXV
Refrigerant Line Connection - Gas (in.)
7/8
Refrigerant Line Connection - Liquid (in.)
3/8
Blower Type
Direct Drive Centrifugal
Configuration
Blow Through
Dimensions (Diameter x Width (in.))
11 x 8
Motor Type
Constant Torque
Nominal CFM
2000
Speed (RPM)
1050
Volts/Ph/Hz
208-230/1/60
Full Load Amps
6.0
Filter Rack (Yes, No)
No
Supply (in.)
12.15 x 21.50
Return (in.)
18.75 x 21.75
Drain Conn. Size (in.)
3/4 NPT
Uncrated (in.)
57-3/8 x 23-1/2 x 21-1/8
Crated (in.)
58-1/8 x 25-7/8 x 25-1/2
Weight - Shipping/Net (lbs.)
185/174

Source documents

Why buy it from Cowboy’s

Sized for your house, installed by the people who answer the phone

We are a Trane Comfort Specialist in San Antonio, family owned since 2007 with forty years in the trade behind the name. Every replacement starts with a load calculation on your home, not the old unit’s nameplate, and the price goes in writing before any work starts. Free in-home estimates; phones answered 24/7.

Call (210) 495-7771

More RunTru air handlers